ac compressor for V5 PV6 DAEWOO NUBIRA/LEGANZA/VECTRA 2.0L
ac compressor for V5 PV6 DAEWOO NUBIRA/LEGANZA/VECTRA 2.0L
Price
US $50-120
Model
INTL-0545
MOQ
1 set

Item specifics

Size
PACKING:28*25*20
Type
Compressor
Car Make
FOR GM V5 DAEWOO NUBIRA/LEGANZA/VECTRA
OE NO.
1131909 , 1135019 , 1135201 , 1135273 , 1135312 , 1135349 , 715021, 96
QUALITY
1 GRADE
GROOVES
6PK

Review

Description

Our factory can produce many kinds of auto Air Conditioner Compressors with good quality and one year quality warrantee. 

 

COMP V5 PV6 DAEWOO NUBIRA/LEGANZA/VECTRA

 

ac compressor for V5 PV6 DAEWOO NUBIRA/LEGANZA/VECTRA 2.0L

 

Specification:

Model number: INTL-0545

Car name:  DAEWOO NUBIRA/LEGANZA/VECTRA

Compressor type: V5

Year Model: 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008

Pulley DIA: 121mm 

Grooves: 6PK 

Voltage: 12V

 

Special Notes:

 

OEM NO.: 1131909 , 1135019 , 1135201 , 1135273 , 1135312 , 1135349 , 715021, 96394697

UAC: CO 10539DC

CarQuest 254367
Daewoo 96271358, 96394697, 96292113, 96394713
Four Seasons 67276

 

Details

Be used for:

2004 Chevrolet Optra L4 2.0L 1998cc 122cid
2005 Chevrolet Optra L4 2.0L 1998cc 122cid
2006 Chevrolet Optra L4 2.0L 2000cc
2005 Suzuki Reno L4 2.0L 1998cc
2006 Suzuki Reno L4 2.0L 1998cc
2007 Suzuki Reno L4 2.0L 1998cc
2008 Suzuki Reno L4 2.0L 1998cc 122cid
1999 Daewoo Leganza L4 2.2L 2200cc

2001 Daewoo Leganza L4 2.2L 2200cc

2002 Daewoo Leganza L4 2.2L 2200cc

2000 Nubira

2001 Nubira

2002 Nubira

 

 

Basic Requirements when servicing an A/C system:

 

1, The Accumulator or Filter Drier should always be replaced when the Air Conditioning System is opened. For warranty Purposes buyer must show evidence of receiver/drier replacement. In some vehicles the drier comes attached to the condenser so it must replaced as well

 

2. A/C system must be clean and free of debris and contaminants. In most cases components can be flushed; however in some instances it may be necessary to replace the condenser or other items.

 

3. Orifice tube must be replaced; expansion valve must be inspected and replaced if dirty or defective.

 

4. Correct amount and type of oil must be used. Please refer to the OE manufacturer for this information.

 

5. Prior to refrigerant charging, full vacuum must be done for a minimum of 45 minutes. In humid climates or during cooler days, this time should be increased to effectively remove air and boil off moisture.

 

6. The Orifice Tube, if equipped, should always be replaced and the Expansion Valve, if equipped, should at least be inspected for proper operation if not replaced