V5 Daewoo Nexia Cielo Espero Chevrolet air ac compressor assembly 96191808 96191807 5110549 5110547 1pk auto a c aircon comp
V5 Daewoo Nexia Cielo Espero Chevrolet air ac compressor assembly 96191808 96191807 5110549 5110547 1pk auto a c aircon comp
Price
US $60-110
Model
INTL-XZC046A
MOQ
1 set

Item specifics

Size
PACKING : 25*22*19
Type
Compressor
Car Make
V5 Daewoo Nexia Cielo Espero Chevrolet
OE NO.
96191808 96191807 5110549 5110547
QUALITY
GRADE ONE
Car name
Daewoo Nexia Cielo Espero Chevrolet
Compressor Type
Delphi-Harrison V5
Clutch
1GA
OEM
96191808 96191807
Delphi-Harrison
5110549 5110547
Daewoo Espero
1995 1996 1997 1998 1999
Daewoo CIELO
1995-1997
Daewoo Nexia
1996-1997
V5 compressor
V5 Chevrolet

Review

Description

Our factory can produce many kinds of auto Air Conditioner Compressors with good quality and one year quality warrantee. 

 

V5 Daewoo Nexia Cielo Espero Chevrolet 1pk ac Kompresor

 

V5 Daewoo Nexia Cielo Espero Chevrolet air ac compressor assembly 96191808 96191807 5110549 5110547 1pk auto a c aircon comp

 

Specification:

Model number: INTL-XZC046A

Car name: Daewoo Nexia Cielo Espero Chevrolet

Compressor Type: Delphi-Harrison V5

Clutch: 1GA
Clutch diameter:138mm
Volt: 12V 

 

Special Notes:

 

OEM#

96191808

96191807

 

Delphi-Harrison:

5110549

5110547

 

Details

 

1995-1999 Daewoo Espero

 

1995-1997 Daewoo CIELO

 

1996-1997 Daewoo Nexia

 

V5 Chevrolet compressor 

 

 

Basic Requirements when servicing an A/C system:

 

1, The Accumulator or Filter Drier should always be replaced when the Air Conditioning System is opened. For warranty Purposes buyer must show evidence of receiver/drier replacement. In some vehicles the drier comes attached to the condenser so it must replaced as well

 

2. A/C system must be clean and free of debris and contaminants. In most cases components can be flushed; however in some instances it may be necessary to replace the condenser or other items.

 

3. Orifice tube must be replaced; expansion valve must be inspected and replaced if dirty or defective.

 

4. Correct amount and type of oil must be used. Please refer to the OE manufacturer for this information.

 

5. Prior to refrigerant charging, full vacuum must be done for a minimum of 45 minutes. In humid climates or during cooler days, this time should be increased to effectively remove air and boil off moisture.

 

6. The Orifice Tube, if equipped, should always be replaced and the Expansion Valve, if equipped, should at least be inspected for proper operation if not replaced