SANDEN TRS105 3026 auto ac compressor Statesman vq vr vs Mitsubishi Pajero nh Holden Commodore vn vp vr vs
SANDEN TRS105 3026 auto ac compressor Statesman vq vr vs Mitsubishi Pajero nh Holden Commodore vn vp vr vs
Price
US $60-120
Model
INTL-XZC602A
MOQ
1 set

Item specifics

Size
PACKING:28*25*20
Type
Compressor, SANDEN TRS105-3026
Car Make
Holden Commodore vn vp vr vs Statesman vq vr vs Mitsubishi Pajero nh
OE NO.
SANDEN TRS105-3026
QUALITY
1 GRADE
1988-1991
Holden Commodore VN
1991-1993
Holden Commodore VP
1993-1995
Holden Commodore VR
1995-1997
Holden Commodore VS
1990-1994
Holden Statesman VQ
Holden Statesman VR
1995-1997
1993-2003
Holden Statesman VS
1991-1997
Mitsubishi Pajero NH

Review

Description

Our factory can produce many kinds of auto Air Conditioner Compressors with good quality and one year quality warrantee. 


SANDEN TRS105 3026 Holden Commodore vn vp vr vs Statesman vq vr vs Mitsubishi Pajero nh ac compressor

SANDEN TRS105 3026 auto ac compressor Statesman vq vr vs Mitsubishi Pajero nh Holden Commodore vn vp vr vs

Specification:

Model No.: INTL-XZC602A

Pulley Dia: 92mm

Type: TRS105

Car:  HOLDEN Mitsubishi

Volt: 12V

Grooves: 1AG


Special Notes:

OEM NO.:

SANDEN 3206

TRS105-3026

3026

 

Application Details


Holden Commodore VN, 1988-1991
Holden Commodore VP, 1991-1993
Holden Commodore VR, 1993-1995
Holden Commodore VS, 1995-1997
Holden Statesman VQ, 1990-1994
Holden Statesman VR, 1995-1997
Holden Statesman VS, 1993-2003
Mitsubishi Pajero NH, 1991-1997

SANDEN TRS105 3026 auto ac compressor Statesman vq vr vs Mitsubishi Pajero nh Holden Commodore vn vp vr vs

Basic Requirements when servicing an A/C system: 

 

1, The Accumulator or Filter Drier should always be replaced when the Air Conditioning System is opened. For warranty Purposes buyer must show evidence of receiver/drier replacement. In some vehicles the drier comes attached to the condenser so it must replaced as well

 

2. A/C system must be clean and free of debris and contaminants. In most cases components can be flushed; however in some instances it may be necessary to replace the condenser or other items.

 

3. Orifice tube must be replaced; expansion valve must be inspected and replaced if dirty or defective.

 

4. Correct amount and type of oil must be used. Please refer to the OE manufacturer for this information.

 

5. Prior to refrigerant charging, full vacuum must be done for a minimum of 45 minutes. In humid climates or during cooler days, this time should be increased to effectively remove air and boil off moisture.

 

6. The Orifice Tube, if equipped, should always be replaced and the Expansion Valve, if equipped, should at least be inspected for proper operation if not replaced